Long-term clinical outcomes of everolimus-eluting stent versus paclitaxel-eluting stent in patients undergoing percutaneous coronary interventions: a meta-analysis.

Clicks: 270
ID: 48868
2016
Everolimus -eluting stent (EES) is common used in patients undergoing percutaneous coronary interventions (PCI). Our purpose is to evaluate long-term clinical outcomes of everolimus -eluting stent (EES) versus paclitaxel-eluting stent (PES) in patients undergoing percutaneous coronaryinterventions (PCI) in randomized controlled trials (RCTs).We searched Medline, EMBASE, Cochrane Library, CNKI, VIP and relevant websites ( https://scholar-google-com.ezproxy.lib.usf.edu/ ) for articles to compare outcomes between everolimus-eluting stent and paclitaxel-eluting stent without language or date restriction. RCTs that compared the use of everolimus -eluting stent and paclitaxel-eluting stent in PCI were included. Variables relating to patient, study characteristics, and clinical endpoints were extracted. Meta-analysis was performed using RevMan 5.2 software.We identified 6 published studies (from three randomized trials) more on everolimus-eluting stent (n = 3352) than paclitaxel-eluting (n = 1639), with follow-up duration ranging from 3, 4 and 5 years. Three-year outcomes of everolimus-eluting stent compared to paclitaxel-eluting were as following: the everolimus-eluting stent significantly reduced all-cause death (relative risk [RR]:0.63; 95% confidence interval [CI]: 0.46. to 0.82), MACE (RR: 0.56; 95% CI: 0.41 to 0.77), MI (RR: 0.64; 95% CI: 0.48 to 0.86), TLR (RR: 0.72; 95% CI: 0.59 to 0.88), ID-TLR (RR: 0.74; 95% CI: 0.59 to 0.92) and ST (RR: 0.54; 95% CI: 0.32 to 0.90). There was no difference in TVR between the everolimus-eluting and paclitaxel-eluting (RR: 0.76; 95% CI: 0.58 to 1.10); Four-year outcomes of everolimus-eluting compared to paclitaxel-eluting: the everolimus-eluting significantly reduced MACE (RR: 0.44; 95% CI: 0.18 to 0.98) and ID-TLR (RR: 0.47; 95 % CI: 0.23 to 0.97). There was no difference in MI (RR: 0.48; 95% CI: 0.16 to 1.46), TLR (RR: 0.46; 95% CI: 0.20 to 1.04) and ST ((RR: 0.34; 95% CI: 0.05 to 2.39). Five-year outcomes of everolimus-eluting stent compared to paclitaxel-eluting: There was no difference in ID-TLR (RR: 0.67; 95% CI: 0.45 to 1.02) and ST (RR: 0.71; 95% CI: 0.28 to 1.80).In the present meta-analysis, everolimus-eluting appeared to be safe and clinically effective in patients undergoing PCI in comparison to PES in 3-year clinical outcomes; there was similar no difference in reduction of ST between EES and PES in long-term(≥ 4 years) clinical follow-ups. Everolimus-eluting is more safety than paclitaxel-eluting in long-term clinical follow-ups, whether these effects can be applied to different patient subgroups warrants further investigation.
Reference Key
meng2016longtermbmc Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Meng, Min;Gao, Bei;Wang, Xia;Bai, Zheng-gang;Sa, Ri-Na;Ge, Bin;
Journal BMC cardiovascular disorders
Year 2016
DOI 10.1186/s12872-016-0206-6
URL
Keywords

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.