Increased mortality and ICD therapies in ischemic versus non-ischemic dilated cardiomyopathy patients with cardiac resynchronization having survived until first device replacement.

Clicks: 253
ID: 47615
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Cardiac resynchronization therapy combined with an implantable cardioverter defibrillator (CRT-D) is widely applied in heart failure patients. Sufficient data on arrhythmia and defibrillator therapies during long-term follow-up of more than 4 years are lacking and data on mortality are conflicting. We aimed to characterize the occurrence of ventricular arrhythmia, respective defibrillator therapies and mortality for several years following CRT-D implantation or upgrade.Eighty-eight patients with ischemic (ICM) or non-ischemic dilated cardiomyopathy (DCM) and at least one CRT-D replacement were included in this study and analyzed for incidence of non-sustained ventricular tachycardia (NSVT), defibrillator shocks, anti-tachycardia pacing (ATP) and mortality.ICM was the underlying disease in 59%, DCM in 41% of patients. During a mean follow-up of 76.4 ±24.8 months the incidence of appropriate defibrillator therapies (shock or ATP) was 46.6% and was elevated in ICM compared to DCM patients (57.7% vs. 30.6%, respectively; = 0.017). Kaplan-Meier analysis revealed significantly higher ICD therapy-free survival rates in DCM patients ( = 0.031). Left ventricular ejection fraction, NSVT per year and ICM (vs. DCM) were independent predictors of device intervention. The ICM patients showed increased mortality compared to DCM patients, with cumulative all-cause mortality at 9 years of follow-up of 45.4% and 10.6%, respectively. Chronic renal failure, peripheral artery disease and chronic obstructive pulmonary disease were independent predictors of mortality.The clinical course of patients with ICM and DCM treated with CRT-D differs significantly during long-term follow-up, with increased mortality and incidence of ICD therapies in ICM patients.
Reference Key
beiert2019increasedarchives Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Beiert, Thomas;Straesser, Swanda;Malotki, Robert;Stöckigt, Florian;Schrickel, Jan W;Andrié, René P;
Journal archives of medical science : ams
Year 2019
DOI 10.5114/aoms.2018.75139
URL
Keywords

Citations