Electrospun P(LLA-CL) Nanoscale Fibrinogen Patch vs Porcine Small Intestine Submucosa Graft Repair of Inguinal Hernia in Adults: A Randomized, Single-Blind, Controlled, Multicenter, Non-Inferiority Trial.
Clicks: 337
ID: 46400
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Star Article
74.8
/100
337 views
269 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
To compare primary efficacy indicators of a low-cost, electrospun, nanoscale P(LLA-CL)/fibrinogen patch with a porcine small intestine submucosa patch for hernia repair.Design: A randomized, single-blind, controlled multicenter trial was performed in 3 hospitals in Shanghai. Eligible patients (20-75 years old) with primary unilateral reducible groin hernias were randomly assigned (1:1) to electrospun nanoscale P(LLA-CL)/fibrinogen patch (experimental group) or porcine small intestine submucosa (control group) patch groups. Patients were treated with the Lichtenstein technique and the primary endpoint was hernia recurrence at 33 months after surgery. The secondary endpoints were postoperative complications including groin pain and operative site infections.Between July 2014 and February 2016, 172 patients were assigned to experimental (n = 86) and control (n = 86) groups. At 6 months follow-up, postoperative complications occurred in 5 patients (5/86, 5·95%) and 2 (2/86, 2·35%) patients in the control and experimental groups, respectively (P<0·05). At 33 months follow-up, recurrence was observed in 2 patients (2/79, 2·53%) in the control group vs none in the experimental group (0/78) (the 95% CI difference between the experimental and control groups was -0·93-6·00% and within the preset non-inferior margin of Δ10%). No significant differences were found in the degree of chronic pain and complications 33 months after surgery between the two groups.Since the recurrence rates and postoperative complications after 33 months were not inferior in the experimental group, we believe that the P(LLA-CL)/fibrinogen patch as a low cost alternative has prospects for widespread clinical use.Reference Key |
li2019electrospunjournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Li, Shaojie;Xiao, Hongbing;Yang, Li;Hua, Lei;Qiu, Zhiying;Hu, Xingchen;Ping, Ding;Zheng, Kan;He, Hongbing;Tang, Jiangxiong; |
Journal | journal of the american college of surgeons |
Year | 2019 |
DOI | S1072-7515(19)32063-0 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.