A radiological inquest to determine the destiny of ultrasound guided trans-muscular quadratus lumborum plane catheters.
Clicks: 302
ID: 43997
2019
After a quadratus lumborum (QL) block, the course of QL plane catheter is unpredictable. This case series discusses the course and fate of trans-muscular QL catheters by following and discussing the contrast spread through the fascial planes. Intrao-peratively, the catheters were tracked by the surgeons and were checked for integrity of anterior thoracolumbar fascia (ATLF) by injecting sterile 0.9% saline. The ATLF was intact upon injection and there was cephalad and medial saline spread with slight bulging of ATLF. On day 3 after written informed consent from all patients, computed tomography (CT) contrast studies were performed. Post-operative contrast spread was variable and was visualised in transversus abdominis plane, QL plane, lower thoracic paravertebral space, inter-vertebral foramina and anterior epidural space. CT contrast images demonstrated a variable spread. In conclusion, injection in ATLF of QL can spread along the path of least resistance and is unpredictable.
Reference Key |
diwan2019aindian
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Diwan, Sandeep;Kulkarni, Medha;Kulkarni, Narendra;Nair, Abhijit; |
Journal | indian journal of anaesthesia |
Year | 2019 |
DOI | 10.4103/ija.IJA_333_19 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.