CT and MR imaging prior to transcatheter aortic valve implantation: standardisation of scanning protocols, measurements and reporting-a consensus document by the European Society of Cardiovascular Radiology (ESCR).
Clicks: 271
ID: 41927
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Transcatheter aortic valve replacement (TAVR) is a minimally invasive alternative to conventional aortic valve replacement in symptomatic patients with severe aortic stenosis and contraindications to surgery. The procedure has shown to improve patient's quality of life and prolong short- and mid-term survival in high-risk individuals, becoming a widely accepted therapeutic option which has been integrated into current clinical guidelines for the management of valvular heart disease. Nevertheless, not every patient at high-risk for surgery is a good candidate for TAVR. Besides clinical selection, which is usually established by the Heart Team, certain technical and anatomic criteria must be met as, unlike in surgical valve replacement, annular sizing is not performed under direct surgical evaluation but on the basis of non-invasive imaging findings. Present consensus document was outlined by a working group of researchers from the European Society of Cardiovascular Radiology (ESCR) and aims to provide guidance on the utilisation of CT and MR imaging prior to TAVR. Particular relevance is given to the technical requirements and standardisation of the scanning protocols which have to be tailored to the remarkable variability of the scanners currently utilised in clinical practice; recommendations regarding all required pre-procedural measurements and medical reporting standardisation have been also outlined, in order to ensure quality and consistency of reported data and terminology. Key Points ⢠To provide a reference document for CT and MR acquisition techniques, taking into account the significant technological variation of available scanners. ⢠To review all relevant measurements that are required and define a step-by-step guided approach for the measurements of different structures implicated in the procedure. ⢠To propose a CT/MR reporting template to assist in consistent communication between various sites and specialists involved in the procedural planning.Reference Key |
francone2019cteuropean
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Francone, Marco;Budde, Ricardo P J;Bremerich, Jens;Dacher, Jean Nicolas;Loewe, Christian;Wolf, Florian;Natale, Luigi;Pontone, Gianluca;Redheuil, Alban;Vliegenthart, Rozemarijn;Nikolaou, Kostantin;Gutberlet, Matthias;Salgado, Rodrigo; |
Journal | European radiology |
Year | 2019 |
DOI | 10.1007/s00330-019-06357-8 |
URL | |
Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.