Two distalization methods compared in a novel patient-specific finite element analysis.

Clicks: 184
ID: 37586
2019
Article Quality & Performance Metrics
Overall Quality Improving Quality
0.0 /100
Combines engagement data with AI-assessed academic quality
AI Quality Assessment
Not analyzed
Abstract
Orthodontic mini-implants aid in the correction of distocclusions via direct anchorage (pull from mini-implant to teeth) and indirect anchorage (teeth pulled against other teeth anchored by the mini-implant). The aim of this study was to compare stress levels on the periodontal ligament (PDL) of maxillary buccal teeth in direct and indirect distalization against orthodontic mini-implants and accounting for individual variation in maxillary anatomy and biomechanical characteristics of the compact bone.A 3D model of the maxilla containing the different components (teeth, PDL, trabecular and cortical bones) was generated from a computed tomographic scan. Cortical bone was divided into several areas according to previously defined zones. Bone stiffness and thickness data, obtained from 11 and 12 cadavers, respectively, were incorporated into the initial model to simulate the individual cortical bone variation at the different locations. Subsequently, a finite element analysis was used to simulate the distalization modalities.Stresses at the buccal, palatal, mesial, and distal surfaces were significantly different between adjacent teeth under stiffness but not thickness variation. In both distalization modalities, low or no significant correlations were found between stress values and corresponding cortical bone thicknesses. High significant and inverted correlations were observed at the first molar between stress amounts and cortical bone stiffness (direct modality: -0.68 < r < -0.72; indirect modality: -0.80 < r < -0.82; P <0.05).With the use of a novel finite element approach that integrated human data on variations in bone properties, findings suggested that cortical bone stiffness may influence tooth movement more than bone thickness. Significant clinical implications could be related to these findings.
Reference Key
ammoury2019twoamerican Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors Ammoury, Makram J;Mustapha, Samir;Dechow, Paul C;Ghafari, Joseph G;
Journal american journal of orthodontics and dentofacial orthopedics : official publication of the american association of orthodontists, its constituent societies, and the american board of orthodontics
Year 2019
DOI S0889-5406(19)30381-6
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.