Delayed post-surgical sepsis from Teflon felt: The diagnostic value of CT scanning, and a reminder for theatre staff
Clicks: 19
ID: 279275
2011
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
We report on 2 patients with surgical site infections following the inadvertent use of Teflon felt for haemostasis in elective and emergency surgery. CT scanning was superior to plain radiography in demonstrating the foreign bodies to enable planning of further surgical treatment.Reference Key |