A modified zeolite/iron oxide composite as a sorbent for magnetic dispersive solid-phase extraction for the preconcentration of nonsteroidal anti-inflammatory drugs in water and urine samples.
Clicks: 379
ID: 2447
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Star Article
80.1
/100
379 views
303 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
This study is the first to use a new ZSM-5 zeolite-based composite decorated with iron oxide magnetic nanoparticles and modified with hexadecyltrimethylammonium bromide surfactant (i.e., HDTMA-ZSM-5/FeO) as an efficient sorbent for magnetic dispersive solid-phase extraction (MDSPE) of nonsteroidal anti-inflammatory drugs in water and urine samples with subsequent measurement by liquid chromatography diode array detection. Experimental factors affecting MDSPE were optimized using a multivariate optimization strategy. The optimum experimental conditions were: amount of sorbent, 40 mg; sample pH, 2.2; NaCl concentration, 2.5%; extraction time, 2 min; eluent solvent, methanol; eluent solvent volume, 424 μL; and elution time, 2 min. The linearity of the method was studied from 3.3 to 400 μg L (N = 8) for ketoprofen, from 1.7 to 400 μg L (N = 8) for felbinac, from 6.6 to 400 μg L (N = 7) for diclofenac and from 9.9 to 400 μg L (N = 6) for ibuprofen. Method repeatability was evaluated at 10 and 200 μg L spiking levels, obtaining coefficients of variation between 2 and 5% (n = 6). Limits of detection, determined empirically, were 1.0 μg L , 0.5 μg L, 2.0 μg L and 3.0 μg L for ketoprofen, felbinac, diclofenac and ibuprofen, respectively. Tap water, reservoir water, wastewater and five urine samples were selected to assess method applicability. Recovery values ranged between 86-107% and 80-112% for water and urine samples, respectively, showing negligible matrix effects. Finally, this method was employed to monitor ibuprofen excretion in real urine samples.Reference Key |
baile2019ajournal
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Baile, Paola;Vidal, Lorena;Canals, Antonio; |
Journal | journal of chromatography a |
Year | 2019 |
DOI | S0021-9673(19)30648-X |
URL | |
Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.