diagnostic accuracy of xpert test in tuberculosis detection: a systematic review and meta-analysis
Clicks: 103
ID: 229499
2016
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Background: World Health Organization (WHO) recommends the use of Xpert MTB/RIF assay for rapid diagnosis of tuberculosis (TB) and detection of rifampicin resistance. This systematic review was done to know about the diagnostic accuracy and cost-effectiveness of the Xpert MTB/RIF assay. Methods: A systematic literature search was conducted in following databases: Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews, MEDLINE, PUBMED, Scopus, Science Direct and Google Scholar for relevant studies for studies published between 2010 and December 2014. Studies given in the systematic reviews were accessed separately and used for analysis. Selection of studies, data extraction and assessment of quality of included studies was performed independently by two reviewers. Studies evaluating the diagnostic accuracy of Xpert MTB/RIF assay among adult or predominantly adult patients (ā„14 years), presumed to have pulmonary TB with or without HIV infection were included in the review. Also, studies that had assessed the diagnostic accuracy of Xpert MTB/RIF assay using sputum and other respiratory specimens were included. Results: The included studies had a low risk of any form of bias, showing that findings are of high scientific validity and credibility. Quantitative analysis of 37 included studies shows that Xpert MTB/RIF is an accurate diagnostic test for TB and detection of rifampicin resistance. Conclusion: Xpert MTB/RIF assay is a robust, sensitive and specific test for accurate diagnosis of tuberculosis as compared to conventional tests like culture and microscopic examination.Reference Key |
kaur2016journaldiagnostic
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | ;Ravdeep Kaur;Kavita Kachroo;Jitendar Kumar Sharma;Satyanarayana Murthy Vatturi;Amit Dang |
Journal | Applied Physics Letters |
Year | 2016 |
DOI | 10.4103/0974-777X.176143 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.