Bone-Plug Versus Soft Tissue Fixation of Medial Meniscal Allograft Transplants: A Biomechanical Study.
Clicks: 249
ID: 20679
2019
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Steady Performance
78.6
/100
249 views
199 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
It is controversial whether soft tissue fixation only and bone-plug techniques for medial meniscal allograft transplantation provide equivalent fixation and restoration of load distribution. Prior studies on this topic did not re-create the clinical situation with use of size-, side-, and compartment-matched meniscal transplants.Both techniques will provide equivalent fixation of the meniscal transplant and restore load distribution and contact pressures similar to those of the native knee.Controlled laboratory study.Nine fresh-frozen human cadaveric knees underwent mean contact pressure, mean contact area, and peak contact pressure evaluation in 4 medial meniscal testing conditions (native, total meniscectomy, bone-plug fixation, and soft tissue fixation) at 3 flexion angles (0°, 30°, and 60°) using Tekscan sensors under a 700-N axial load.Medial meniscectomy resulted in significantly decreased contact area and increased contact pressure compared with the native condition at all flexion angles ( < .0001). Compared with the native state, soft tissue fixation demonstrated significantly higher mean contact pressure and lower mean contact area at 0° and 30° of flexion ( < .05), while bone-plug fixation showed no significant difference. There was no significant difference in peak contact pressure between study conditions.Total medial meniscectomy leads to significantly worsened load distribution within the knee. Medial meniscal allograft transplantation can restore load parameters close to those of the native condition. The bone-plug technique demonstrated improved tibiofemoral contact pressures compared with soft tissue fixation.Medial meniscal allograft transplantation with bone-plug fixation is a viable option to restore biomechanics in patients with meniscal deficiency.Reference Key |
ambra2019boneplugthe
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Ambra, Luiz Felipe;Mestriner, Alexandre Barbieri;Ackermann, Jakob;Phan, Amy T;Farr, Jack;Gomoll, Andreas H; |
Journal | The American journal of sports medicine |
Year | 2019 |
DOI | 10.1177/0363546519870179 |
URL | |
Keywords | Keywords not found |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.