troponin-i is not falsely elevated in asymptomatic dialysis patients
Clicks: 76
ID: 154744
2013
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Dialysis patients with troponin-I levels above the cut-off value diagnostic for acute myocardial event (AME) are sometimes labeled as having "renal cause" of elevated troponin-I. Patients with troponin-I levels above 0.0 ng/mL, but below the cut-off level for an AME, are reported to have increased risk for coronary heart disease and mortality. Single pre-dialysis blood samples were taken from 150 asymptomatic dialysis patients (on hemo- or peritoneal dialysis) for troponin-I, cardiac enzymes, C-reactive protein (CRP) and lipid parameters. Troponin-I was measured by a chemiluminescent microparticle immunoassay (CMIA), of which the cut-off value for AME was set at ā„0.4 ng/mL. Patients with troponin-I levels of 0.0 ng/mL, and those with levels between 0.1 and 0.3 ng/mL, were compared regarding their cardiovascular risk profile. None of the patients had troponin-I concentrations above the cut-off level diagnostic for an AME, with 85.3% of the patients having levels of 0.0 ng/mL. While there was no difference in the "traditional" risk factors such as age, body mass index, prevalence of diabetes mellitus, hypertension, total cholesterol and low-density lipoprotein cholesterol between patients with troponin-I levels of 0.1-0.3 ng/mL and those with levels of 0.0 ng/mL, CRP concentrations were higher in the former. In peritoneal dialysis patients, the weekly Kt/V was lower in the patients with troponin levels between 0.1 and 0.3 ng/mL. The findings should add strong support in settling the debate of whether or not in patients on dialysis, falsely elevated levels of troponin-I "commonly" occur. An increased level of CRP and lower Kt/V might add to the cardiovascular risk in patients with troponin-levels between 0.1 and 0.3 ng/mL.Reference Key |
hussein2013sauditroponin-i
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | ;Magdi M Hussein;Jaap M Mooij;Najla Al Malki;Tarek M Demerdash;Abdullah Y Mandourah |
Journal | 15th ibero-american conference on software engineering, cibse 2012 |
Year | 2013 |
DOI | 10.4103/1319-2442.106240 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.