temperature monitoring in large volume spread footing foundations: case study "parque da cidade" - são paulo

Clicks: 179
ID: 136362
ABSTRACT In recent years, the construction of foundation elements from large-volume reinforced concrete is becoming increasingly common. This implies a potential increase in the risk of cracks of thermal origin, due to the heat of hydration of cement. Under these circumstances, these concrete elements need to be treated using the mass concrete theory, widespread in dam construction, but little used when designing buildings. This paper aims to present a case study about the procedures and problems involved in the construction of a spread footing with a volume of approximately 800m³ designed for the foundation of a shopping center in São Paulo, Brazil.
Reference Key
coutorevistatemperature Use this key to autocite in the manuscript while using SciMatic Manuscript Manager or Thesis Manager
Authors ;D. Couto;P. Helene;L. C. Almeida
Journal psychotherapies
Year Year not found
DOI 10.1590/s1983-41952016000600007
URL
Keywords Keywords not found

Citations

No citations found. To add a citation, contact the admin at info@scimatic.org

No comments yet. Be the first to comment on this article.