buckling and post-buckling of prestressed stainless steel stayed columns
Clicks: 258
ID: 131663
2017
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
Prestressed stayed compression members are frequently required as very slender load-bearing structural components by both investors and architects. Behavior of these members depends on their geometrical and material properties, prestressing and boundary conditions. In the paper are discussed respective critical buckling loads and post-buckling paths with regards to 2D and 3D GMNIA (geometrically and materially nonlinear analysis with imperfections) using ANSYS software. Former tests and recent detailed analyses of other authors are commented with respect to the 3D analysis, level of imperfections, boundary conditions at central crossarm (fixed or sliding stays) and nonlinear stainless steel material.Reference Key |
pichal2017engineeringbuckling
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | ;Radek Pichal;Josef Machacek |
Journal | engineering structures and technologies |
Year | 2017 |
DOI | 10.3846/2029882X.2016.1277169 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.