Comparison of Drusen Volume Assessed by Two Different OCT Devices
Clicks: 192
ID: 115834
2020
Article Quality & Performance Metrics
Overall Quality
Improving Quality
0.0
/100
Combines engagement data with AI-assessed academic quality
Reader Engagement
Emerging Content
0.3
/100
1 views
1 readers
Trending
AI Quality Assessment
Not analyzed
Abstract
To compare drusen volume between Heidelberg Spectral Domain (SD-) and Zeiss Swept-Source (SS) PlexElite Optical Coherence Tomography (OCT) determined by manual and automated segmentation methods. Thirty-two eyes of 24 patients with Age-Related Macular Degeneration (AMD) and drusen maculopathy were included. In the central 1 and 3 mm ETDRS circle drusen volumes were calculated and compared. Drusen segmentation was performed using automated manufacturer algorithms of the two OCT devices. Then, the automated segmentation was manually corrected and compared and finally analyzed using customized software. Though on SD-OCT, there was a significant difference of mean drusen volume prior to and after manual correction (mean difference: 0.0188 ± 0.0269 mm3, p < 0.001, corr. p < 0.001, correlation of r = 0.90), there was no difference found on SS-OCT (mean difference: 0.0001 ± 0.0003 mm3, p = 0.262, corr. p = 0.524, r = 1.0). Heidelberg-acquired mean drusen volume after manual correction was significantly different from Zeiss-acquired drusen volume after manual correction (mean difference: 0.1231 ± 0.0371 mm3, p < 0.001, corr. p < 0.001, r = 0.68). Using customized software, the difference of measurements between both devices decreased and correlation among the measurements improved (mean difference: 0.0547 ± 0.0744 mm3, p = 0.02, corr. p = 0.08, r = 0.937). Heidelberg SD-OCT, the Zeiss PlexElite SS-OCT, and customized software all measured significantly different drusen volumes. Therefore, devices/algorithms may not be interchangeable. Third-party customized software helps to minimize differences, which may allow a pooling of data of different devices, e.g., in multicenter trials.Reference Key |
beck2020journalcomparison
Use this key to autocite in the manuscript while using
SciMatic Manuscript Manager or Thesis Manager
|
---|---|
Authors | Marco Beck;Devika S. Joshi;Lieselotte Berger;Gerd Klose;Sandro De Zanet;Agata Mosinska;Stefanos Apostolopoulos;Andreas Ebneter;Martin S. Zinkernagel;Sebastian Wolf;Marion R. Munk;Beck, Marco;Joshi, Devika S.;Berger, Lieselotte;Klose, Gerd;De Zanet, Sandro;Mosinska, Agata;Apostolopoulos, Stefanos;Ebneter, Andreas;Zinkernagel, Martin S.;Wolf, Sebastian;Munk, Marion R.; |
Journal | journal of clinical medicine |
Year | 2020 |
DOI | 10.3390/jcm9082657 |
URL | |
Keywords |
Citations
No citations found. To add a citation, contact the admin at info@scimatic.org
Comments
No comments yet. Be the first to comment on this article.